sart positioner
- Model Number: ALP2100-SERIES
- Brand Name: AERLP
- Place of Origin: ANHUI, United States
- Minimum Order Quantity: 1
- Supply Capacity: 3000/month
- Payment: T/T
- MemberShip: Free Member
- Inquiry Now
ALP2100-SERIES sart positioner Description
1.?Overview
1.1 ?Performance ?profile??of??the ?ALP210??The??ALP210??uses??a??microcontroller electronic control?unit, the?PID exact?algorithm?of?the??pneumatic?instrument. With?keys, LCD?dot?array?screen?display,?HART??communication?and?MSBUS?communication?functions.?Adopt?modular?structure,?compact,?strong,?reasonable?design.?High?cost?performance,?simple??maintenance, to avoid unnecessary user?costs.
operation?panel
ALP locator built-in operation panel, equipped with 3 keys and LCD?LCD display, simple and convenient?operation.?With?simple?debugging?and?automatic,?manual?operation?switching?function.?Can?facilitate?the?stroke adjustment and automatic sealing?function?to?open?and?close.?You?can also view?the run?parameters.
Pneumatic?performance
With many years of experience in pneumatic?instrument design,?the?carefully optimized single-action and dual-action amplifier structure?brings?great?convenience?to?users?and?saves?the?use?cost.?Modular?structure, easy?to?repair,?replacement.?The?ALP locator is?equipped?with?two output interfaces, blocking an output interface is a single-action?valve positioner, and can also change the interface to change the form?of the?valve?action.
communication
ALP has two?modes of communication, MSBUS?can?be?used?to?connect?to??a?dedicated?operator?or?computer,?HART?communication?module (not?standard,?selected when purchase) can be connected to HART operator or?(through??HART-adjustment demodulator) to the?computer.
signal?output
ALP?has?the?valve?position?feedback?function (not?standard,?selected
Instructions?Version?Number::20/01-2.01-CN
?
function?when?purchase),?using?the?two-line?loop?power?supply?technology,?the?power supply?voltage drop is?less?than?6VDC?at?20mA.?No?calibration,?automatic follow, the accuracy is?better than 0.5%. modular?structure
ALP adopts modular design structure, circuit board control?module,?pneumatic amplifier?module, I / P?conversion?module, sensor?module,?can?be very convenient maintenance and replacement.
Principle ?structure??diagram
the?key?technical?indexes
1. Input signal?range:?4~20mA; the?dividing?range is?4~12mA?and?12~20mA.?2. Feedback signal range: 4~20mA; the?range?is?4~12mA?and?12~20mA.
3. Equivalent resistance: 425?Ω?(625?Ω; HART protocol?type)
4. Control accuracy:?0.5%
5. Lineity:?1%
6. Sensitivity: adaptive; or artificially set during which the period?is?0.1%~5%
7. Gas supply pressure range:?0.14~0.55MPa
8.?Gas?consumption:?static?gas?consumption?is?50NL?/?h?;?dynamic?unassessment
9. Environmental conditions: temperature: -25~ +?60℃?; humidity:?90%
10. Dynamic resistance: 2g?(5~200HZ)
11. Safety parameters: Ui=28VDC;Ii=93mA;Pi=0.65W;Ci=1nF;Li=0.2mH;
12. Storage conditions: temperature: -40~?+?85℃?;?humidity:?95%
13. Protection?level:?IP66
Programmable?parameters
1. Enter the?starting point?range:?4~12mA
2. Input?end?point?range:?12~20mA
3. Input?signal:?convertable?direction
4. Output signal:?convertable?direction
5. Off limit: starting?point?0~10%?End?point?ranged?from?90%?to?110%
6. Trip adjustment: starting point?0~30% End?point?is?70%?to?100%
7. Trip?time:?0~200S
Instructions?Version?Number::20/01-2.01-CN
?
8. Output characteristics: linear,?1:25,1:50?optional
9. Tolerance band: 0.1%~10% adjustable
10. PID parameters:?tunable
ALP210?Main?part?names?and?functions
?
component
explain
body
Housing, upper cover, position?sensor
Control panel,?circuit?unit
Control circuit?board, shortcut operation?keys
I /?P?electrical?conversion module
Telecom signal-to-gas signal?conversion?module
pneumatic amplifier
The?amplifier?will?generate?the?gas signal?from?I?/?P?to?control?the?actuator?intake?and?exhaust.
Pressure gauge??connection module
Indicates the?input and?output pressure.
Feedback rod
Transfer the openness?signal to?the?position
sensor.
Additional circuit?unit
Integrated in?the?control?circuit?board?when?an
additional 4-20mA position feedback unit or a
HART protocol unit?is selected.
?
2、Explosion-proof,?safety?and?wiring
?
2.1 ?Security?overview
This?product?has?passed?the?strict?factory?test?and?meets?the?requirements?of?IEC3836.4:2010.?In order to?ensure?this?good?condition?during?the?running time, the requirements of the instructions and valid documents?and certificates must be followed,?and the routine safety regulations?must?be?followed?when?operating?the?equipment.?In?addition?to?the?regular?safety procedures, descriptions or?operating?instructions?along?with?specific?safety?tips.?Only?pay?attention?to?all?safety?tips,?can?effectively prevent personnel and the environment from harm, reliable?and normal use of?equipment.
2.2?Use?of?regulations
Instructions?Version?Number::20/01-2.01-CN
?
The ALP210 locator is designed and manufactured for the application?of?"pneumatic?output?valve?locator?for?industrial?process?control?system",?and is installed on the?direct?stroke?or?rotary pneumatic actuator?as??required?in?the instructions.?This?equipment?can?only?be?used?as?specified?in?the?operating instructions?and?parameters.?Any?other?use?of?violations?will not be permitted. Input signal circuit / feedback output?circuit??wiring must meet the explosion-proof requirements?(see 2.3 Safety
explosion-proof requirements for details) The maximum allowable?ambient?temperature range is-40...65 C Do?not?repair?the circuit?part?and?remove?other explosion-proof related devices without authorization.
2.3?Anti-explosion-proof?requirements
2.3.1 The product?must be?matched?with?the safety?grid?certified?by?the explosion-proof inspection agency?to?form?the?primary?safety
explosion-proof system.?Safety?parameters?are?as?follows: Input circuit?(terminal?± IN) Ui=28V,li=93mA Pi=0.66W,Ci=1nF,Li=0.2mH Output
circuit?(terminal?± OUT) Ui=28V,li=93mA Pi=0.66W,Ci=1nF,Li=0.2mH 2.3.2 The connection between the?product?and the?safety?gate?safety?end?shall be a shielding cable?with a section of> 0.5mm2,?and?the shielding?layer must be grounded. Cable distribution capacitance and inductance?value must be less than?the?safety?value.?2.3.3?The?safety?gate?is
installed in a?safety place, and?it must?comply with?the?operating
instructions. 2.3.4?Users shall?not change the?electrical?components in?the products at will. 2.3.5 When installing, using and maintaining the?products, users must comply with both the Power Plant Design Code and?the?relevant?GBV3836.15-2000?regulations?of?the?"GB50058-92".?”2.4?Wiring?2.4.1 Input and valve position?feedback?control?signal The?input?and feedback signals of?ALP210 shall?be?used in explosion-proof?situations,?with the range of 4~20mADC?(limit value?3.8-24mA). Signal?cables:?To
Instructions?Version?Number::20/01-2.01-CN
?
prevent external interference signals,?shield?cables with?a?maximum ?length?of 1280m?are?recommended.?Control?cables?are laid separately?from?the power?cables.
Equivalent resistance: | 425 Ω (625 Ω; HART protocol type) |
---|---|
Control accuracy: | 0.5% |
Lineity: | 1% |
Sensitivity: adaptive; or artificially set during | 0.1%~5% |
Protection level: | IP66 |
Storage conditions: temperature: | -40~ + 85℃ |
ex proof | exiadIIct6 |
Gas supply pressure range: | 0.14~0.6MPa |
Retaled category: Angle Valve